Search
You can find the results of your search below.
Fulltext results: measuring_quantum_yield @howto 8 Hits , Last modified: 7 years ago ple holder.
* Put the sample holder into the IN-position .
* Put the sample holder into the integrating s... 14-35-37.jpg?600 |}}
* Select either IN or OUT position
**Note:** The sample holder has two indexed positions. When in the IN position , the excitation beam will directly hit the sample, when in the OUT position the sample will only be illuminated indirectly (b some_origins_of_multiexponetial_decays_for_single_dyes 2 Hits , Last modified: 5 years ago place. Hence the system is always in its starting position $(A + X)$ prior to any excitation pulse.//
//Cas... 1 state and brings the system to a more favorable position . Spectroscopically, this is manifested by the tim fluorescence_correlation_spectroscopy-_a_short_introduction @general 1 Hits , Last modified: 16 months ago uestion: \\ ** how far inside the sample can one position the focal volume and still get a reasonable FCS c 2ffcs @howto 1 Hits , Last modified: 9 years ago the time trace oscilloscope optimize the pinhole position **with** Nomarski Prism and **both** lasers.
align_beam_backreflection @howto 1 Hits , Last modified: 22 months ago ch quadrant. To reach this, you have to precisely position the beam to enter at the center of the objective diamond_nv_centers @howto 1 Hits , Last modified: 6 years ago w NV-centers (see figure 5),
*select one, and position the focus on the NV-center.
*use the oscillos how_to_measure_the_instrument_response_function_irf @howto 1 Hits , Last modified: 9 months ago or upon changes of the excitation wavelength, the position of the IRF can shift slightly, but this is accoun how_to_work_with_the_instrument_response_function_irf @howto 1 Hits , Last modified: 16 months ago power of the laser changes the shape and temporal position of the laser pulse. ((You can use the driver sett intensity_time_trace_analysis @howto 1 Hits , Last modified: 10 years ago return from the end of the line to the line start position is done with highest possible speed. In contrast, select_the_correct_pinhole_size @howto 1 Hits , Last modified: 9 years ago ger than the image of the [[wp>Airy Disc]] at the position of the pinhole:
$$d_{Airy} = (1.22 * lambda / N. using_the_antibunching_script @howto 1 Hits , Last modified: 10 years ago lly moves the red and yellow curve to the correct position . Press "Calculate" again to recalculate the corre symphotime64 @software 1 Hits , Last modified: 10 years ago ng language ("STUPSLANG") even puts the user in a position to freely add new analysis procedures or customiz